Similar to invasive mechanical ventilation, non-invasive mechanical ventilation can also provide effective respiratory support to patients with respiratory failure by improving ventilation and gas exchange, reducing the consumption of respiratory work.
Indications
1. People with respiratory insufficiency and no contraindications can try a non-invasive ventilator.
1) Acute respiratory failure and acute exacerbation of chronic respiratory failure.
2) Acute cardiogenic pulmonary edema.
3) Persistent asthma.
4) Transition before weaning of invasive ventilation.
5) Neuromuscular diseases.
6) Sleep apnea and obesity hypopnea syndrome (Pickwickian Syndrome).
2. Non-invasive ventilation can be used as the first-line treatment for patients with acute exacerbation of COPD and acute cardiogenic pulmonary edema.
3. Patients with respiratory failure with immunosuppression can try non-invasive ventilation first.
Contraindications
1. Absolute contraindications:
1) The heartbeat stops breathing.
2) Weak spontaneous breathing and coma.
3) Patients who are prone to aspiration.
4) Combined with failure of other organs (hemodynamic instability, gastrointestinal hemorrhage/perforation, severe brain disease, etc.).
5) Facial trauma/postoperative/deformity.
6) Uncooperative patients.
2. Relative contraindications:
1) Excessive airway secretions, sputum expectoration disorder.
2) With severe infection.
3) Extremely nervous patients.
4) Severe hypoxemia (PaO₂<45mmHg, severe acidosis pH≤7.20).
5) After recent upper abdominal surgery (especially those who need strict gastrointestinal decompression).
6) Severely obese patients.
7) Patients with mechanical obstruction of the upper airway. In units with better monitoring conditions and rich experience, under the premise of close observation, it can be used as an exploratory application to patients with relatively contraindications.
Applicable departments
· ICU, emergency department, respiratory department, neurosurgery · Cardiac Surgery, General Surgery, Pediatrics · Geriatrics, Oncology · Departments of oxygen therapy and non-invasive positive pressure ventilation support
High flow oxygen therapy (HFNC) mode
Operatin mode | 2 types of HFLOW\LFLOW |
Flow range | HFLOW: 10-80L/min LFLOW: 2-25L/min |
Temperature adjustment | 29--37*C. step 1C (temperature 34'C in LFLOW mode) |
Alarm function | Breathing circuit alarm/ leak alarm/ blocking alarm/ Fail to reach target flow alarm/ Fail to reach target temperature alarm/ Check working environment alarm |
Supplies | Heated breathing circuit humidification tank kit |
Patient interface | Nasal plug type nasal oxygen tube, tracheostomy connector, children's nasal oxygen tube, oxygen mask |
Non-invasive ventilator (NIV) mode
Ventilation mode | CPAP\S\T\ST\PC\MVAPS total 6 types |
Positive Inspiratory Pressure (IPAP) cmH2O | 4-40 |
Positive expiratory pressure (EPAP) cmH2O | 4-20 |
Continuous positive pressure (CPAP) cmH2O | 4-20 |
Delay boost (min) | 0-60 (CPAP mode) 0-3 (S\T\STPC\MVAPS mode) |
Pressure rise time S | 0.1-0.6/Auto (S\T\ST\PC\MVAPS mode) |
Monitor tidal volume ml | 100-2500 |
Inspiratory time S | 0.5-3.0 (T\ST\PC\MVAPS mode) |
Inspiratory trigger sensitivity | 1-6 gears/auto |
Exhalation switching sensitivity | 1-6 gears/auto |
Breath rate BPM | 2-40 |
Automatic compensation (deep air volume) | 260L/min |
Temperature adjustment | 29-34'C, step 1C |
Alarm function | Pipe falling alarm/leak alarm/ventilation alarm/high and low breathing rate alarm low-minute ventilation alarm |
Supplies | Patient interface oronasal mask, nasal mask |
System parameters
Fan | Custom imported fan |
Oxygen concentration setting | 0.21-1.0 step 0.01 (NIV mode or HFNC mode, both can realize automatic control) |
Humidification method | Integrated integrated humidification method, automatic adjustment according to multi-parameter sensor data |
Backup battery | Optional uninterruptible power supply (fixed for car treatment). Maximum standby time 7 8 hours 37C60/min50 phen clock (HFLOW mode 0) /34CIPAP30omH2O EPAPSomH2060 minutes (NM mode D) |
screen | 4.5 inch touch screen |
Trolley | Customized trolley (standard cantilever, optional backup power supply and oxygen cylinder bracket) |
Call the police | Low oxygen concentration alarm/high oxygen concentration alarm/internal fault alarm/check water volume alarm/power failure alarm |
Connect the pipeline | Active heating pipeline adopts special heating wire technology |
power supply | 220VAC: 22V, 50+1Hz |
Device grade | Type 1 BF |
waterproof level | IP21 |
Operating temperature | 18-28C |
Host weight | 2.5kg |
Alarm volume | >45dB (A) (1m distance) |
Disinfection method | Portable rechargeable ozone generator (optional) |
Our Company
Shenyang Maisi Medical Technology Co., Ltd. is a high-tech emerging modern enterprise specializing in the development, production, sales and service of respiratory diagnosis and treatment and electronic products. It is a domestic company with core technology covering 2 major respiratory therapy equipment.
The company is headquartered in Hunnan High-tech Development Zone, Shenyang City, Liaoning Province. The company covers an area of more than 6000 square meters. The current main products are high-flow respiratory humidification therapy equipment (HFNC), non-invasive ventilation therapy equipment (BiPAP AutoBiPAP and Auto-CPAP) . The company's products have passed the US FDA, EU CE, RoHS and South Korea GMP certification, and strictly implement ISO13485, ISO9001 and national and industry related standards in every link of development and production. The product quality is stable and reliable, and has been universally recognized by customers all over the world.
The company's technical core backbone is composed of a team of technical experts from the fields of domestic information technology, automation control, machinery manufacturing and medical technology. The company has good cooperation with Air Force Aviation Medical Research Institute, China Medical University and other well-known domestic units.
Since its founding, Maxx Medical has forged ahead and has become a brand influential enterprise in the field of respiratory support in China. To create the future and not forget the original intention, Max Medical will strive to become an excellent brand of respiratory support in China.
Maisi has many years of experience in product development in the respiratory therapy industry, and has won a number of patents. The perfect after-sales service has brought us more and more users and sold to more than a dozen countries and regions. Based on the principle of good quality and customer first, we will dedicate effective and reliable products to customers with superb and innovative technical strength, advanced equipment and good service attitude.
Use advanced technology to serve clinical respiratory medicine and seek welfare for patients with respiratory diseases.
With professional integrity, we provide advanced, convenient and economical sleep and breathing treatment programs for patients with respiratory diseases.
FAQ
1. Are you a manufacturer or trading company?
RE:We are a manufacturer specilized in respirtory products,including Noninvasive Ventilators, HFNC and Oxygen Concentrators.
2. Do you have any certification?
RE:We are CE and EN ISO 13485 approved and FDA is in application and will be available in near future.
3. How long is your product warranty period?
RE:2 years.